Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM00178

Parcel: 11008305F


Addresses:

2485 N SWAN RD #161


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T07CM00178

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
05/31/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
05/30/2007 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
04/02/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
OK FOR RESTROOM AREA & MOP SINK
(2) FLOOR SINKS AT SOUTH WALL LOCATION UNDERGROUND WITH TRAP PRIMERS & PIPE WRAPS.
HAVE A SET OF PLANS ON SITE WITH READABLE CITY APPROVAL PLAN CHECK STAMP.
03/26/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) PLANS APPEAR TO HAVE CITY APPROVAL BUT IT IS NOT CLEAR WHO EXAMINED THESE PLANS
2) 3 COMP SINK REQUIRES TWO COMPARTMENTS TO CONNECT DIRECTLY TO SEWER. VEGTABLE PREP SINK SHAL DRAIN INDIRECTLY
3) YOU MAY NOT HORIZONTAL WET VENT LAVS OVER FLOOR DRAINS
4) RED LINE ANY CHANGES TO PLAN. REVISION REQUIRED FOR FINAL
5) SUPPORT HORIZONTAL WASTE PIPING
6) OK TO COVER MAIN LINE CONNECTION AT TOILET ROOMS
7) OK TO COVER FLOOR DRAINS AND ?
8) PERM CAP DEMOED VENTS