Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T07CM00176
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/08/2007 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
10/03/2007 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MISSING RECEPTACLE @ SERVICE COVER 2. MISSING ENTRY LIGHT FIXTURE (EXTERIOR) 3. HAVE OPEN SPLICES/WIRING ON EXTERIOR 4. CORD NOT PROPERLY CONNECTED TO SUB-PANEL, PANEL MISSING COVER SCREW 5. MAKE SURE CHASIS AND WATER/GAS PROPERLY GROUNDED/BONDED 6. SMOKE DETECTORS TO BE NO CLOSER THAN 4" TO CEILING 36" AWAY FROM HVAC VENTS 7. HAVE SEVERAL LOOSE/CRACKED DEVICES AND PLATES RECEPTACLES TO BE FLUSH WITH COVER PLATE. REPLACE PAINTED DEVICES. 8. HAVE OPEN WIRING IN CAB. ABOVE SINK, MISSING FURNACE J-BOX COVER ETC. NO OPEN WIRING PERMITTED THROUGHOUT 9. NEED T-STAT COVER 10. KITCHEN, BATH, EXTERIOR RECEPTACLES TO BE GFI PROTECTED 11. INSTALL FIXTURE LIGHT BULBS |