Permit: T07CM00176

Parcel: 107051080


Addresses:

2928 N 15TH AV #30


Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T07CM00176

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
10/08/2007 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
10/03/2007 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. MISSING RECEPTACLE @ SERVICE COVER
2. MISSING ENTRY LIGHT FIXTURE (EXTERIOR)
3. HAVE OPEN SPLICES/WIRING ON EXTERIOR
4. CORD NOT PROPERLY CONNECTED TO SUB-PANEL, PANEL MISSING COVER SCREW
5. MAKE SURE CHASIS AND WATER/GAS PROPERLY GROUNDED/BONDED
6. SMOKE DETECTORS TO BE NO CLOSER THAN 4" TO CEILING
36" AWAY FROM HVAC VENTS
7. HAVE SEVERAL LOOSE/CRACKED DEVICES AND PLATES
RECEPTACLES TO BE FLUSH WITH COVER PLATE. REPLACE PAINTED DEVICES.
8. HAVE OPEN WIRING IN CAB. ABOVE SINK, MISSING FURNACE J-BOX COVER ETC. NO OPEN WIRING PERMITTED THROUGHOUT
9. NEED T-STAT COVER
10. KITCHEN, BATH, EXTERIOR RECEPTACLES TO BE GFI PROTECTED
11. INSTALL FIXTURE LIGHT BULBS