Permit: T07CM00172

Parcel: 127070080

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/17/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/28/2008 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
OK CEILING AFTER CORRECTIONS TO CEILING

1. SUPPORT MC CABLE TO MOVED LIGHTS
2. REMOVE ABANDONED CABLING 725.3
3. LABEL DISCONNECT
4. ATTACH DISCONNECT TO STRUCTURE
5. TIGHTEN LOOSE FITTING
6. TIGHTEN CONDUCTOR TERMINATIONS
7. BOND DISCONNECT
8. USE APPROVED HARDWARE FOR SUPPORTS AND CORRECT SIZE STRAPS

*VERIFY LIGHTING ADDED IN WALL - POOL ROOM

9. BOND JUNCTION BOX ENCLOSURE