Permit: T07CM00135

Parcel: 105123450

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T07CM00135

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/04/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/27/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLOSET FLANGES NOT APPROVED
2) CONTRACTOR TO PAY REINSPECTION FEE
09/21/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE UPC SECS 316 AND INSTALLATION STANDARDS FOR ABS CLOSET FLANGES
09/18/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
05/21/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER ALL AREAS
NEED TO SEE FIRST FLOOR FLANGES
05/18/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
ABS IS TO BE SUPPORTED AT EACH FLOOR AND MID-STORY SUPPORT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES -- THEN NO MORE THAN FOUR FEET BETWEEN HANGERS.

ALL CLOSET FLANGES ARE TO BE SECURED TO THE FLOOR WITH CORROSION RESISTANT SCREWS.