Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/05/2007 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
| 08/22/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* REPLACE BLK NIPPLE UPSTREAM OF IRR ASSEM INSTALL UNION |
|
| 08/17/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1" CU AT SERVICE OK IS PVC RISER SHOWN ON PLAN? DOOR LOCKED |
|
| 08/15/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1" TYPE L COPPER REQUIRED AT TRAILER REMOVE EXCESS FLUX PVC PER REDLINES OK CONNECTION AT RP OK |
|
| 08/13/2007 | PLUMBING - YARD WTR LINE/TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NOT INSTALLED PER PLAN 2. NOT INSTALLED PER REDLINES 3. WHERE DOES IRRIGATION SUPPLY CONNECT TO DOMESTIC YARDWATER PIPING? 4. WIPE EXCESS FLUX OFF OF FITTINGS 5. RPPBP IS DUMPING 6. PVC YARDWATER PIPING WILL REQUIRE 12" OF COVER AT ALL POINTS. |