Permit: T07CM00118

Parcel: 123122180

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/19/2007 FRAMING Approved IVRS - Inspection :*
04/18/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MAKE UP SWITCHES PIG TAIL GROUNDS
2) GROUND METAL BOXES
3) CEILING BOXES NOT RATED FOR FANS
03/30/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BOLTS MISSING AT ANGLE WALL N. SIDE
2) MAKE UP ALL BOXES
3) PROTECT WIRES CLOSER THAN 1 1/4" TO FACE OF STUD
03/09/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. HALLWAY NEEDS TO BE A MINIMUM OF 36" WIDE