Permit: T07CM00094

Parcel: 134180100


Addresses:

7342 E BROADWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/25/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
03/30/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER WALLS
PROPERLY ALIGN MISSION COUPLINGS
BREAKER SINK TO BE INSTALLED UNDER A SEPARATE PERMIT PER PLAN NOTES.
03/27/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. A 3 X 1 1/2 SANTEE AND AN 1 1/2 SWEEP ARE THE CORRECT DRAINAGE FITTINGS PREVIOUSLY NOTED.
2. MISSION COUPLINGS USED ON SCH40 PLASTIC SHALL BE LISTED FOR PLASTIC TO PLASTIC, AND SHALL BE UNIFORMLY TIGHTENED.
3. CLEANOUTS SHALL BE MADE WATER TIGHT W/THREAD SEALANT.
4. CO AT LAV SHALL BE ACCESSIBLE
5. MAKE CONNECTION AT EXISTING LAV WASTE
6. BREAK ROOM SINK SHOWN ON PLAN
03/23/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
03/22/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE LONG RADIUS DRAINAGE FITTING PER NOTES ABOVE.
2. PROVIDE TEST ON WASTE & VENT SYSTEM
3. PROVIDE 2" CLEANOUT ON LAV RISER
4. COMPLETE WORK SHOWN PER PLAN
03/19/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE PLANS
LAVITORY TRAP ARM SHALL BE 1 1/2" MAX
DRAINAGE FITTING REQUIRED AT CHANGE OF DIRECTION
FERNCO COUPLINGS NOT ALLOWED IN BUILDING
REMOVE AND CAP LAVITORY PIPING