Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/25/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 03/30/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER WALLS PROPERLY ALIGN MISSION COUPLINGS BREAKER SINK TO BE INSTALLED UNDER A SEPARATE PERMIT PER PLAN NOTES. |
|
| 03/27/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. A 3 X 1 1/2 SANTEE AND AN 1 1/2 SWEEP ARE THE CORRECT DRAINAGE FITTINGS PREVIOUSLY NOTED. 2. MISSION COUPLINGS USED ON SCH40 PLASTIC SHALL BE LISTED FOR PLASTIC TO PLASTIC, AND SHALL BE UNIFORMLY TIGHTENED. 3. CLEANOUTS SHALL BE MADE WATER TIGHT W/THREAD SEALANT. 4. CO AT LAV SHALL BE ACCESSIBLE 5. MAKE CONNECTION AT EXISTING LAV WASTE 6. BREAK ROOM SINK SHOWN ON PLAN |
|
| 03/23/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 03/22/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. SHALL PROVIDE LONG RADIUS DRAINAGE FITTING PER NOTES ABOVE. 2. PROVIDE TEST ON WASTE & VENT SYSTEM 3. PROVIDE 2" CLEANOUT ON LAV RISER 4. COMPLETE WORK SHOWN PER PLAN |
|
| 03/19/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE PLANS LAVITORY TRAP ARM SHALL BE 1 1/2" MAX DRAINAGE FITTING REQUIRED AT CHANGE OF DIRECTION FERNCO COUPLINGS NOT ALLOWED IN BUILDING REMOVE AND CAP LAVITORY PIPING |