Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/15/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE |
|
| 02/08/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE FUSES IS DISCONNECT 35 AMP MAX 2) PAINT EXPOSED PVC WITH LATEX PAINT 3) PROVIDE 1/8" PER FT. SLOPE ON ALL SECTIONS 4) TERMINATE WITHIN 6" OF THE GROUND WITH AN ELBOW AND NIPPLE 5) WHAT HAPPENED TO THE DOWNSPOUT ? |
|
| 01/29/2007 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* BREAKERS FOR HEAT PUMP NOT SIZED RIGHT |
|
| 01/08/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* CONDENSATE CANNOT DRIP OUT OF SCUPPER ONTO A SIDEWALK. USE THE OTHER SCUPPER & TERMINATE WITHIN 6" OF THE GROUND WITH AN ELBOW & NIPPLE. DIVERT THE WATER AWAY FROM THE HOUSE. PROVIDE 1/8" PER FT. SLOPE ON 1ST SECTION OF DRAIN PIPE. SCRATCH OFF DATA PLATE NEXT TO THE PROPER HEAT STRIP INSTALLED & FUSE ACCORDINGLY. |