Permit: T07CM00072

Parcel: 124060830

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T07CM00072

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/12/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
02/06/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSPECTION FOR UNIT #2
1. NEED LIGHT FIXTURE OR SWITCHED RECEPTACLE FOR BEDROOMS
2. INSTALL RANGE ANTI-TIP DEVICE
3. USE ONLY SQ D BREAKERS IN SQ D PANEL
4. PANEL DIRECTORY TO BE CORRECTLY IDENTIFIED
5. BATHROOM RECEPTACLES TO BE GFI PROTECTED
6. KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED
7. EXTERIOR RECEPTACLES TO BE GFI PROTECTED
8. NEED COUNTERTOP RECEPTACLE BETWEEN RANGE AND REFER
9. HAVE SEVERAL LOOSE RECEPTACLES
10. SMOKE DETECTOR TO BE MINIMUM 36" AWAY FROM
HVAC VENT
11. PROVIDE SERVICE RECEPTACLE FOR HVAC UNIT

INSPECTION FOR UNIT #2 ONLY - CHECK SAME #1 - NO PLANS ON SITE?