Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07BU02657

Parcel: 121070140


Addresses:

5975 E SPEEDWAY BL

Inspection Status: Denied

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
04/08/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PLEASE APPLY FOR A MECHANICAL PERMIT FOR REPLACEMENT OF TYPE 1 REQUIREMENT ON ROOF NO LATER THAN
APRIL 18, 2008 PERMIT MUST BE OBTAINED NO LATER THAN MAY 16, 2008 ALL WORK TO BE COMPLETED BY JUNE 6, 2008
(SIGNED BY JESSE SANDERS)
03/19/2008 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
- SEE NOTES FROM PREVIOUS INSPECTION
- PROVIDE A MECHANICAL PERMIT & APPROVED PLANS FOR REPLACEMENT OF EXHAUST EQUIPMENT
- INTERLOCK MAKE UP AIR WITH EXHAUST FANS
- DUCTS ON ROOF NOT APPROVED FOR TYPE I
- PROVIDE INSTALL INSTRUCTIONS FOR CLEANOUT DOORS
12/28/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- BLOWERS NOT APPROVED FOR TYPE 1 HOODS
STANDARD DUT BLOWERS NOT APPROVED FOR GREASE LADEN EXHAUST
- POWER TO MAKE UP AIR DISCONNECTED
- CLEANOUT DOORS ON GREASE DUCT NOT APPROVED
- GREASE DUCT WITHIN 18" OF COMBUSTIBLE MATERIAL