Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07BU02610

Parcel: 12514016B


Addresses:

3164 E 4TH ST

Inspection Status: Approved

Inspection History: GRADING - INTERMEDIATE

Date Description Inspector Results Comments
07/14/2011 GRADING - INTERMEDIATE Approved
06/15/2011 GRADING - INTERMEDIATE Continued MET W/ SUPERINTENDENT , CHECKED FORMS FOR PEDESTRIAN ACCESS FROM ROW. RAMP SLOPE WAS OK.
06/14/2011 GRADING - INTERMEDIATE Continued SIDEWALK CONSTRUCTED IN FRONT OF BLDGS ON SITE NEEDS RAILING IN TWO SPOTS / BOTH SPOTS THE SLOPE IS >5% BUT <8.3%.
PEDESTRIAN ACCESS FROM ROW NEEDS TO BE NO GREATER THAN 8.3% AS SHOWN ON THE APPROVED GRADING PLAN.
04/19/2011 GRADING - INTERMEDIATE Continued MINIMAL SITE WORK ASSOCIATED WITH THIS PROJECT, HOWEVER CONTRACTOR MUST ENSURE PARKING, ACCESS, AND DRAINAGE PER APPROVED PLANS.

DUE TO LIMITED SPACE, KEEP AN EYE ON DIMENSIONS AND SLOPES.
03/31/2011 GRADING - INTERMEDIATE Continued NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME
03/01/2011 GRADING - INTERMEDIATE Continued NO SITE WORK CURRENTLY BEING CONSTRUCTED.
ISSUE W/ADAAG-ANSI ACCESS NOT SOLVED.
NO STORM WATER CONCERNS
02/08/2011 GRADING - INTERMEDIATE Continued PEDESTRIAN ACCESS FROM ROW TO EACH HOUSE IS NOT ADAAG/ANSI COMPLIANT. SIDEWALK SLOPES CONNECTING EACH HOUSE ARE >5% WITH A RISE > 6".
SWEEP ADJACENT STREET, CLEAN UP CONCRETE WASH OUT
01/06/2011 GRADING - INTERMEDIATE Continued NO SITE WORK BEING DONE. CONTRACTOR ROUGH GRADING FOR RESIDENTIAL LOTS AND ROAD.
NO STORM WATER CONCERNS AT THIS TIME
11/08/2010 GRADING - INTERMEDIATE Not ready for Inspection NO CONTACT, NO ACTIVITY ON SITE