Permit: T07BU02522

Parcel: 133363290


Addresses:

9912 E MANASSAS PL

Inspection Status: Approved

Inspection History: POOL/SPA PLUMBING

Date Description Inspector Results Comments
06/09/2008 POOL/SPA PLUMBING Approved IVRS - Inspection :*
06/06/2008 POOL/SPA PLUMBING Cancelled IVRS - RI canceled
06/04/2008 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*
1) INSTALL VACUUM BREAKERS ON HOSE BIBS
2) WALL ON EAST SIDE NEAR POOL EQUIPMENT IS NOT 5' FROM THE OUTSIDE
01/18/2008 POOL/SPA PLUMBING Partial Approval IVRS - Inspection :*
1) INSTALL VACUUM BREAKER ON HOSE BIB
2) BOND WIRES FOR EQUIPMENT AND FOR BONDING RING RUN
3) CONDUIT TO POOL EQUIPMENT AND LIGHTS RUN TO AREA OF CHIMNEY
4) WIRES NOT RUN
5) BOND RING NOT INSTALLED
6) IF NO SVRS IS TO BE USED SUPPLY UL LISTING FOR SLIT DRAIN SINGLE 3" PIPE
7) RECALL FOR INSPECTION OF BONDING RING AFTER GRADING