Permit: T07BU01949

Parcel: 11812051A


Addresses:

234 E 22ND ST

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
05/16/2008 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
05/13/2008 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. PROVIDE PROPER BANDING ON FIRE WRAP
2. REMOVE ACCESS FOR INSPECTION (DOOR)
3. PROVIDE GREASE TROUGH ON ROOF
4. PROVIDE CHAIN ON ROOF TO SUPPORT EXHAUST FAN
5. PROPERLY SEAL ROOF CURB ON EXHAUST FAN
6. REMOVE BOLTS PENETRATING HOOD
03/24/2008 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
- 1ST LAYER OF GREASE DUCT WRAP OK
- PROVIDE PROPER ACCESS DOOR PRIOR TO SECOND LAYER OF WRAP
- PROVIDE INSTALLATION INSTRUCTIONS FOR ACCESS DOOR AND INSULATION PRIOR TO NEXT INSPECTION
- MAINTAIN 3" OVERLAP AT SECOND LAYER OF WRAP
03/17/2008 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
LIGHT TEST ON GREASE DUCT OK
OK FOR 1ST LAYER WRAP
03/13/2008 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
03/13/2008 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
REFEE WILL APPLY TO NEXT INSPECTION
03/07/2008 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
03/05/2008 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
02/25/2008 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK FOR SECOND LAYER OF WRAP