Permit: T07BU01909

Parcel: 107080120


Addresses:

805 W GLENN ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/02/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) NEED TO DIG ALONG SIDE TWO POST SUPPORTS TO VERIFY DEPTH-SO I CAN APPROVE EXCAVATION/LAYOUT ON ACTIVITY CARD
09/17/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO CLIP 2 X 8 TO 4 X 6 BEAM WITH A34-2 PLACES
2) NEED H25 ON 2 X 6 RAFTER TO EXISTING
3) KNOCKOUT ALL SHINERS IN ROOF NAILING AND RE-NAIL
4) DRAWING CALLS FOR T11 SIDING-NEED TO CHANGE ON PLANS OR FOLLOW PLANS