Permit: T07BU01869

Parcel: 14041055A

Inspection Status: Approved

Inspection History: POOL/SPA ELECTRIC

Date Description Inspector Results Comments
04/04/2008 POOL/SPA ELECTRIC Approved IVRS - Inspection :*
04/02/2008 POOL/SPA ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTES LAST INSP.
04/01/2008 POOL/SPA ELECTRIC Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. GROUND WIRE ON EAST END NEEDS PHYSICAL PROTECTION BETWEEN PUMPS.
2. PLANS/PERMIT MUST BE POSTED ON SITE
3. SEE NOTE FOR GROUNDING OF PANEL LAST INSP.
4. UNCOVER EQUIP. FOR INSP.
03/20/2008 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
OK LIGHT FIXTURES IN POOL & SPA
FINAL ELECTRICAL INSPECTION WILL NOT BE MADE BEFORE WATCH IS IN AND ALL IS COMPLETE AND OPERATIONAL

*NOTE: POOL EQUIPMENT PANEL WILL NEED GROUND RODS SEE NEC 250.32
03/10/2008 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
OK PERIMETER GROUNDING, SLEEVES, ESCUTIONS
03/07/2008 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
12/10/2007 POOL/SPA ELECTRIC Partial Approval IVRS - Inspection :*
- OK GROUNDING IN POOL, SPA, LAZY RIVER & U.G
CONDUIT FEEDS TO LIGHTS, GROUNDING NOT COMPLETE ON EAST SIDE OF POOL TO J-BOXES. SUBJECT TO APPROVED PLANS.
- DO NOT COOL DECK UNTIL ALL GROUNDING IS CONNECTED TO SLEEVES, ESCUTIONS