Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - FINAL
Permit Number - T07BU01857
Inspection Description - GRADING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/16/2009 | GRADING - FINAL | Approved | SPOKE WITH ENGINEER OF RECORD (EDWIN BRUCE WILSON) FROM EEC AND HE STATED THAT HE WOULD PROVIDE A CERT STATEMENT REMOVING THE WATER HARVESTING BASIN SHOWN ON THE APPROVED GRADING PLAN. THE EOR PROVIDED A REVISED DRAWING SHOWING CHANGES MADE TO THE ACCESS ROAD. |
|
04/08/2009 | GRADING - FINAL | Continued | NO RESPONSE TO INSPECTION RESULTS, NO REVISED PLAN, NO CONTACT WITH CONTRACTOR AND/OR OWNER. | |
02/10/2009 | GRADING - FINAL | Correction Required | MET WITH CONTRACTOR AND TEP ON SITE. PRIOR TO FINAL GRADING APPROVAL, PROVIDE AN APPROVED REVISED GRADING PLAN SHOWING CHANGES MADE TO THE SITE TO INCLUDE: 4" SCUPPER W/CONCRETE INLET INSTALLED ACCROSS ACCESS ROADWAY ROCK RIP RAP BIRM INSTALLED AS A FLOW DISAPATOR IN DRAINAGE CHANNEL OMMISSION OF WATER HARVESTING BASIN ALONG THE SW CORNER OF THE SITE. CONTACT NAME: KAREN W/DIVERSIFIED CONSTRUCTION 327-7384 EXT130 |
|
01/12/2009 | GRADING - FINAL | Partial Approval | SITE READY FOR FINAL GRADING INSPECTION, NO ACTIVITY ON SITE. CONTACTED OWNER, NO RESPONSE | |
12/30/2008 | GRADING - FINAL | Not ready for Inspection | SPOKE WITH REPRESENTATIVE OF TEP ON CLOSING OUT GRADING PERMIT. SHE STATED THAT WORK HAS BEEN ACCOMPLISHED AND THEY WILL CALL IN FOR A FINAL GRADING INSPECTION. | |
07/31/2008 | GRADING - FINAL | Not ready for Inspection | NOT ALL SITE WORK HAS BEEN COMPLETED. |