Inspection Status: Approved
Inspection History: ENGINEERING PRE-CONSTRUCTION
Permit Number - T07BU01830
Inspection Description - ENGINEERING PRE-CONSTRUCTION
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/14/2008 | ENGINEERING PRE-CONSTRUCTION | Approved | ||
11/02/2007 | ENGINEERING PRE-CONSTRUCTION | Partial Approval | NO APPROVED GRADING PERMIT FOR SITE YET. SEDIMENT CONTROLS INSTALLED AT CATCH BASINS NEAR CONSTRUCTION AREA AND AT ALL STORM WATER CURB OUTLETS. ENSURE TO CONTINUE TO SWEEP UP TRACKING OF SOIL OFF OF PARKING AREA. |
|
10/25/2007 | ENGINEERING PRE-CONSTRUCTION | Correction Required | MET WITH CONTRACTOR TO DISCUSS PROJECT AT HAND. PROJECT WILL INCLUDE DEMOLITION, SITE GRADING AND CONSTRUCTION OF NEW BUILDINGS. NO EXISTING GRADING PERMIT OR PLAN. HAVE STORM WATER PLAN AND SUBMITTED NOI TO STATE. CONTRACTOR NOT IN COMPLIANCE WITH SWPPP. MUST IMPLEMENT THE SWPPP PRIOR TO THE START OF DEMO WORK OR CONSTRUCTION. STORM WATER PLAN REQUIRES : 1) NO CONCRETE OR MATERIALS TO BE WASHED OUT ON SITE. 2) PROVIDE TEMPORARY STORM WATER INLET PROTECTION DURING CONSTR 3) ALL HUAL TRUCK LOADS MUST BE COVERED. 4) SWEEP SITE DAILY 5) INSTALL STABILIZED CONSTR ENTRANCE (MAY NOT NEED IT) 6) INSTALL SILT FENCE WHERE APPROPRIATE (?) WILL RE-INSPECT FOR COMPLIANCE. |