Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07BU01830

Parcel: 10511061E


Addresses:

4490 N ORACLE RD


Inspection Status: Approved

Inspection History: ENGINEERING PRE-CONSTRUCTION

Permit Number - T07BU01830

Inspection Description - ENGINEERING PRE-CONSTRUCTION

Inspection Status - Approved

Date Description Inspector Results Comments
02/14/2008 ENGINEERING PRE-CONSTRUCTION Approved
11/02/2007 ENGINEERING PRE-CONSTRUCTION Partial Approval NO APPROVED GRADING PERMIT FOR SITE YET.
SEDIMENT CONTROLS INSTALLED AT CATCH BASINS NEAR CONSTRUCTION AREA AND AT ALL STORM WATER CURB OUTLETS.
ENSURE TO CONTINUE TO SWEEP UP TRACKING OF SOIL OFF OF PARKING AREA.
10/25/2007 ENGINEERING PRE-CONSTRUCTION Correction Required MET WITH CONTRACTOR TO DISCUSS PROJECT AT HAND.
PROJECT WILL INCLUDE DEMOLITION, SITE GRADING AND CONSTRUCTION OF NEW BUILDINGS.
NO EXISTING GRADING PERMIT OR PLAN.
HAVE STORM WATER PLAN AND SUBMITTED NOI TO STATE.
CONTRACTOR NOT IN COMPLIANCE WITH SWPPP. MUST IMPLEMENT THE SWPPP PRIOR TO THE START OF DEMO WORK OR CONSTRUCTION.

STORM WATER PLAN REQUIRES :

1) NO CONCRETE OR MATERIALS TO BE WASHED OUT ON SITE.
2) PROVIDE TEMPORARY STORM WATER INLET PROTECTION DURING CONSTR
3) ALL HUAL TRUCK LOADS MUST BE COVERED.
4) SWEEP SITE DAILY
5) INSTALL STABILIZED CONSTR ENTRANCE (MAY NOT NEED IT)
6) INSTALL SILT FENCE WHERE APPROPRIATE (?)

WILL RE-INSPECT FOR COMPLIANCE.