Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
Permit Number - T07BU01629
Inspection Description - POOL/SPA FINAL/BARRIER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/23/2007 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* SVRS #025805 |
|
11/19/2007 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EAST GATE NOT ACCEPTABLE-LATCHING MECHANISM 2) NEED TO INSTALL ONE-WAY SCREW IN WINDOWS TO LIMIT OPENING TO 4" |
|
11/13/2007 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PRESSURE RELIEF PIPING NEEDS TO TERMINATE 6" FROM GROUND 2) GATES NEED TO BE SELF LATCHING AND SELF CLOSING 3) NEED TO TIE UP DOGS SO I CAN INSPECT OTHER GATE OPENING 4) NO VACUUM RELIEF SYSTEM AT THIS TIME 5) WINDOWS NEED TO BE FIXED WHERE THEY CANNOT BE OPENED NO MORE THAN 4" |