Permit: T07BU01599

Parcel: 122130330


Addresses:

4015 E SPEEDWAY BL

Inspection Status: Partial Approval

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
01/03/2008 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
- HOOD & GREASE DUCT UP TO ROOF ARE OK TO USE
- THE BLOWER & RELATED DUCTING ON ROOF IS NOT
APPROVED FOR TYPE 1 USE. REPLACE UTILITY BLOWER & DUCT ON ROOF. BLOWER & DUCT MUST BE PART OF AN ENGINEERED SYSTEM APPROVED BY CITY OF TUCSON
12/28/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
HOOD IS TYPE 2 WHICH IS NOT APPROVED FOR CONVEYOR PIZZA OVENS. THIS HOOD NEEDS TO BE TYPE 1