Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - FINAL
Permit Number - T07BU01542
Inspection Description - GRADING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/24/2010 | GRADING - FINAL | Approved | ||
01/26/2010 | GRADING - FINAL | Correction Required | MET ON THE SITE WITH THE CONTRACTOR/DEVELOPER AND DISCUSSED THE ISSUES THAT I SEE ON THIS SITE AT THIS TIME. THE FOLLOWING ITEMS HAVE BEEN NOTED AS INCOMPLETE AT THIS TIME AND WILL NEED TO BE CORRECTED PRIOR TO CALLING IN FOR THE FINAL GRADING INSPECTION. 1) THE DETENTION BASIN AND WATER HARVESTING BASIN BOTH HAVE STANDING WATER IN THEM. THE LAST RAINS WERE WELL OVER 24 HOURS AGO, SO THESE AREAS ARE DRAINING PROPERLY. THE LIMIT ON THIS SITE IS 12 HOURS PER THE PIMA COUNTY / CITY OF TUCSON STORMWATER MANUAL FOR A SITE SMALLER THAN 10 ACRES. 2) INSTALL THE BIKE RACKS AS NOTED ON THE APPROVED PLANS. 3) PROVIDE THIS OFFICE WITH A SET OF APPROVED AS-BUILT DRAWINGS SHOWING ALL MODIFICATIONS THAT HAVE BEEN MADE TO THIS SITE. THIS WILL INCLUDE BUT IS NOT LIMITED TO THE REMOVAL OF THE HAND RAIL ON THIS SITE THAT IS SHOWN ON THE CURRENT APPROVED PLANS. 4) AN ACCESS WAY FROM MAC ARTHUR HAS BEEN PROVIDED, BUT WE ARE BEING ADVISED THAT THIS ACCESS POINT WILL BE LOCKED AT ALL TIMES. THIS ACCESS IS PART OF A ZONING REQUIREMENT TO PROVIDE PEDESTRIAN ACCESS TO ALL LOCAL STREETS ADJACENT TO THIS SITE. TO LOCK THIS GATE WILL REQUIRE A NOTIFICATION FROM THE ZONING DEPARTMENT THAT THIS IS AN ACCEPTABLE PRACTICE. IF THIS IS NOT DONE PRIOR TO FINAL ACCEPTANCE YOU MAY NOT RECEIVE YOUR FINAL C OF O AT THAT TIME. THERE IS A QUESTION ABOUT THE NON-USE OF FILTER FABRIC AT THE LOCATIONS OF THE ROCK RIP RAP WITHIN YOUR DRAINAGE STRUCTURES. THIS WILL BE CHECKED PRIOR TO PERFORMING THE FINAL INSPECTION ON THIS SITE FOR THE GRADING PERMIT. |
|
01/25/2010 | GRADING - FINAL | Correction Required | SPOKE WITH ART HILL REGARDING FINAL INSPECTION. ADDRESSED REMAINING ITEMS. ART WILL CALL IN A FINAL INSPECTION FOR TOMORROW. | |
03/17/2009 | GRADING - FINAL | Partial Approval | Stop Work Order removed from site. OK to start wall perimeter wall construction. |