Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T07BU01528
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/15/2007 | REINFORCED MASONRY PRE-GROUT | Approved | ||
10/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU RETAINING WALL REINFORCEMENT STEEL @ SOUTH INTERIOR RAMP WALL |
|
10/17/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* REINFORCEMENT STEEL @ LOWER EAST RETAINING WALL FROM 2'8" TO 6'8" ABOVE TOP OF FOOTING |
|
10/11/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. EAST LOWER RETAINING WALL 0' TO 2'8" ABOVE TO F 2. LOWER S/E SCREEN WALL 0 TO 5'4" ABOVE TO F |
|
09/28/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 100 L.F OF CMU SITE WALL - 200 FEET E. OF S.W CORNER TO 2 FOOT 4 INCH ABOVE TOP |
|
09/27/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* FIRST 100 L.F OF SOUTH SITE WALL FROM S/W CORNER 1ST LIFT TO 4'8" ABOVE TOP OF FOOTING |
|
09/21/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT OF 59 L.F NORTH RETAINING WALL |
|
09/20/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH, EAST AND SOUTH RETAINING WALL FROM 9 TO 13 AFF |
|
09/19/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) STEEL REINFORCEMENT AT LOWER SECTION OF NORTH SIDE RAMP 0' TO 59' WEST OF SOUTH EAST CORNER OF RAMP |
|
09/12/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST RETAINING WALL 8' TO 12' -- 3RD LIFT SOUTH RETAINING WALL 4' TO 8' -- 2ND LIFT |
|
09/10/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH RETAINING WALL TO 3 FOOT 4 INCHES OK TO GROUT |
|
09/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1ST LIFT NORTH PROPERTY LINE WALL FROM N/E CORNER 20 L.F TO WEST |
|
09/06/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH SIDE OF CONCRETE DOWN RAMP FROM 11' HIGH RETAINING WALL S/E CORNER 84 L.F FROM EAST TO WEST 1ST LIFT -- OK TO GROUT |
|
08/30/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU RETAINING WALL TO 4 FEET 1ST LIFT @ EAST END NORTH TO SOUTH, AS PER DETAIL 2 ON SHEET C4 |