Permit: T07BU01528

Parcel: 13507330J


Addresses:

7620 E 22ND ST

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
11/15/2007 REINFORCED MASONRY PRE-GROUT Approved
10/19/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU RETAINING WALL REINFORCEMENT STEEL @ SOUTH INTERIOR RAMP WALL
10/17/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
REINFORCEMENT STEEL @ LOWER EAST RETAINING WALL FROM 2'8" TO 6'8" ABOVE TOP OF FOOTING
10/11/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. EAST LOWER RETAINING WALL 0' TO 2'8" ABOVE TO F
2. LOWER S/E SCREEN WALL 0 TO 5'4" ABOVE TO F
09/28/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
100 L.F OF CMU SITE WALL - 200 FEET E. OF S.W CORNER TO
2 FOOT 4 INCH ABOVE TOP
09/27/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
FIRST 100 L.F OF SOUTH SITE WALL FROM S/W CORNER
1ST LIFT TO 4'8" ABOVE TOP OF FOOTING
09/21/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT OF 59 L.F NORTH RETAINING WALL
09/20/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH, EAST AND SOUTH RETAINING WALL FROM 9 TO 13 AFF
09/19/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) STEEL REINFORCEMENT AT LOWER SECTION OF NORTH SIDE RAMP 0' TO 59' WEST OF SOUTH EAST CORNER OF RAMP
09/12/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST RETAINING WALL 8' TO 12' -- 3RD LIFT
SOUTH RETAINING WALL 4' TO 8' -- 2ND LIFT
09/10/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH RETAINING WALL TO 3 FOOT 4 INCHES
OK TO GROUT
09/07/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT
NORTH PROPERTY LINE WALL FROM N/E CORNER
20 L.F TO WEST
09/06/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH SIDE OF CONCRETE DOWN RAMP FROM 11' HIGH RETAINING WALL S/E CORNER 84 L.F FROM EAST TO WEST
1ST LIFT -- OK TO GROUT
08/30/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU RETAINING WALL TO 4 FEET 1ST LIFT @ EAST END
NORTH TO SOUTH, AS PER DETAIL 2 ON SHEET C4