Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/30/2007 | POOL/SPA FINAL/BARRIER | Approved | IVRS - Inspection :* | |
| 08/27/2007 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SVRS #022958 2) INSPECTION REPORT FROM LAST INSPECTION NOT IN PLAN TUB 2) NEED NON REVERSABLE SCRE IN WINDOW TRACK, 4" OPENING 3) 5' HT REQUIRED SOUTH WALL, DITCH AT BOTTOM OF WALL NOT ACCEPTABLE |
|
| 07/31/2007 | POOL/SPA FINAL/BARRIER | Not ready for Inspection | 1) INSTALL VACUUM BREAKER ON HOSE BIB 2) BOND WIRES AND CONDUIT FROM EQUIPMENT AREAS TO LIGHT OK 3) CONDUIT FROM MAIN PANEL TO EQUIPMENT NOT RUN |
|
| 07/24/2007 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO CLEANOUT POOL & MUD OFF REBAR |
|
| 07/20/2007 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED SVRS SYSTEM INSTALLED 2) FINISH POOL ENCLOSURE PATIO WALLS TO BE MINIMUM 5'-0" 3) POOL BARRIER MINIMUM 4'-0", ALSO BOND METAL BARRIER WITHIN 5' OF H20 EDGE |