Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - INTERMEDIATE
Permit Number - T07BU01296
Inspection Description - GRADING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/11/2008 | GRADING - INTERMEDIATE | Approved | ||
03/19/2008 | GRADING - INTERMEDIATE | Partial Approval | MET ON SITE WITH KELLY EGAN 602 332 5015 REFERRED ZONING QUESTION TO HEATHER THRALL REGARDING WALK-IN DISCUSSED SITE WORK AND PROGRESS |
|
03/13/2008 | GRADING - INTERMEDIATE | Partial Approval | CURBING BEING INSTALLED | |
02/12/2008 | GRADING - INTERMEDIATE | Partial Approval | CHANGE IN FINISH FOR DUMPSTER ENCLOSURE FAUX STONE WILL NOT BE PLACED-BLOCK WILL BE PAINTED TO MATCH BUILDING-NO REVISION REQUIRED |
|
02/05/2008 | GRADING - INTERMEDIATE | Partial Approval | CHANGE TO PAVING PLAN RATHER THAN ALL CONCRETE-ASPHALT WILL BE PLACED IN ALL AREAS OTHER THAN DRIVE THRU, TRASH ENCLOSURE AND LOADING ZONE OK'D AS-BUILT RATHER THAN RE-REVIEW |
|
01/25/2008 | GRADING - INTERMEDIATE | Partial Approval | SITE VISIT TALKED TO KELLY RE DRAIN IN TRASH ENCLOSURE THE DRAIN HAS BEEN REMOVED AT THIS TIME |
|
01/17/2008 | GRADING - INTERMEDIATE | Correction Required | CONCERNS ABOUT DRAIN IN TRASH ENCLOSURE Our Development Standard, Section 6.4.2.C1 reads as follows: C. Enclosures for dumpster containers are as follows. 1. The base shall be a concrete slab with an inside clear dimension of ten (10) feet by ten (10) feet by five (5) inches thick. Restaurants and other food service establishments are required to provide a sewer-connected drain in the center of the slab to facilitate container cleaning. Pima County's Title 13.36.060.C2 reads as follows: Prohibited wastes C. Industrial wastewater that may cause dilution or POTW hydraulic loading problems, including, but not limited to: 1. Any water added for the purpose of diluting wastes which would otherwise exceed maximum concentration limits; 2. Any rainwater, screenwriter runoff, groundwater, street drainage, roof drainage, yard drainage, water from yard fountains, ponds, swimming pools, lawn sprays or uncontaminated water except where prior approval for such discharge is given by the director Our design criteria appears to be diametrically opposed to Pima County's wishes and, more importantly, their ordinance. TALKED TO DON WILHOITE 740-6500 AND DOUG KIRKLAND 579-5771 AT PC REGARDING THIS ISSUE |
|
01/16/2008 | GRADING - INTERMEDIATE | Partial Approval | From: Heather Thrall To: Nichole Kalahar Zormeier Date: 01/16/2008 9:30 AM Subject: RE: Whataburger 6504 E. 22nd Street - T07BU01296 - Bike parking Good morning Nichole, Regarding the lack of class I bike parking spaces on Whataburger, there is a provision that says that if a site has under 50 parking spaces that the class 2 parking spaces are acceptable for the class I spaces as well. He's got 25 parking spaces on his site, so he can use the 4 class 2 spaces for the total number of bike spaces he needs, per the LUC 3.3.4 Thanks for checking - very good! |
|
01/16/2008 | GRADING - INTERMEDIATE | Partial Approval | MET WITH BIANCA REGARDING DRAIN IN TRASH ENCLOSURE PART OF DEV STD BUT MAY NOT BE ACCEPTABLE TO PC LEFT MESSAGE WITH MIKE REDMOND 10:07A 740-3340 ASKING FOR CLARIFICATION |
|
01/16/2008 | GRADING - INTERMEDIATE | Partial Approval | STOPPED AT SITE TO ADVISE KELLY OF CHANGE TO BIKE PARKING-PROVIDED COPY OF EMAIL AS WELL AS DEV STD DESCRIBING APPROPRIATE BIKE RACKS |