Inspection History Details
Inspection Status: Closed
Inspection History: GRADING - INTERMEDIATE
Permit Number - T07BU01161
Inspection Description - GRADING - INTERMEDIATE
Inspection Status - Closed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/05/2020 | GRADING - INTERMEDIATE | Closed | SITE HAS NOT BEEN CONSTRUCTED PER THE APPROVED PLANS AND THIS PERMIT INSPECTION IS CLOSED AT THIS TIME. PLANS HAVE BEEN DESTROYED | |
05/17/2017 | GRADING - INTERMEDIATE | Continued | MET WITH RON AND BRAD ON THE SITE TO LOOK OVER THE WATER SYSTEMS THAT HAVE BEEN INSTALLED. WE ASKED BRAD TO RESEACH THE APPROVAL OF THE METERS, AND LOOKED TOO SEE IF THE SITE WAS ABLE TO CONTINUE. WE DISCUSSED THE PAAL WIDTHS MAYBE NARROW AND THERE IS QUESTIONS IN REGARDS TO THE WALLS THAT HAVE BEEN CONSTRUCTED, THEY MAY NEED TO BE INSPECTED BY A STRUCTURAL ENGINEER TO SEE IF ALL OF THE MATERIAL IS STILL ACCEPTABLE DUE TO THE TIME THAT HAS PASSED SINCE THEY WERE ORIGINALL CONSTRUCTE. BRAD WILL TRY TO PROVIDE US ADDITIONAL INFORMATION BEFORE ANOTHER INSPECTION IS CALLED IN., | |
08/23/2011 | GRADING - INTERMEDIATE | Continued | NO ACTIVITY AT THIS TIME. | |
07/15/2011 | GRADING - INTERMEDIATE | Continued | WALKED SITE WITH PAUL MACHODO. | |
05/10/2011 | GRADING - INTERMEDIATE | Continued | WALKED SITE WITH JIM . NO ACTIVITY AT THIS TIME. | |
04/25/2011 | GRADING - INTERMEDIATE | Continued | NO ACTIVITY. | |
10/28/2010 | GRADING - INTERMEDIATE | Continued | NO CHANGES TO SITE. | |
10/01/2010 | GRADING - INTERMEDIATE | Continued | NO CHANGES TO SITE. | |
09/21/2010 | GRADING - INTERMEDIATE | Approved | NO ACTIVITY ON SITE. | |
09/07/2010 | GRADING - INTERMEDIATE | Approved | NO ACTIVITY ON SITE. SOME OF THE CAUTIONARY FENCING HAS BEEN REMOVED FROM THE PRIVATE PROPERTY SIDE OF PROJECT. | |
08/30/2010 | GRADING - INTERMEDIATE | Continued | STORMWATER CONTROLS WERE BEING INSTALLED ON SITE. | |
08/03/2010 | GRADING - INTERMEDIATE | Continued | NO ACTIVITY ON SITE. | |
06/18/2010 | GRADING - INTERMEDIATE | Continued | Met with Mac Hudson, Terry Van Wie, and Brad Gephart at site to discuss safety, access, and erosion control for the site. Mac explained that the ward office has received many calls regarding the property, they would like to see the property secured without a big ugly fence. I suggested a post and cable fence might work as well. Brad will look into this. I also explained what needed to be done to get the site in conformance with the AZPDES permit, new waddel, and sand bags need to be placed, street sweeped. | |
06/11/2010 | GRADING - INTERMEDIATE | Continued | CONSTUCTION FENCING HAS BEEN REMOVED. NOTHING TO PREVENT ACCESS TO SITE BUT A FEW BLOCKS AT ACCESS POINTS | |
05/04/2010 | GRADING - INTERMEDIATE | Continued | CONSTRUCTION FENCING HAS BEEN REESTABLISHED. BANK REP. TO CALL IN TO SCHEDULE MEETING WITH REP. TO DISCUSS PROPERTY. | |
04/12/2010 | GRADING - INTERMEDIATE | Correction Required | SPOKE WITH BRAD GEPHART OF ADVANCE CAPITAL, 326-8059. ADDRESSED CONCERNS OF FENCING DOWN IN RIGHT-OF-WAY AND STORMWATER CONTROLS. WHEN HE HAS RESOLVED THESE ISSUES HE WILL CONTACT US FOR A MEETING REGARDING THE FUTURE OF THIS PROPERTY. | |
04/06/2010 | GRADING - INTERMEDIATE | Correction Required | Advanced capital 326-8059, called and left message that repairs need to be done at this site. Security fence is down and erosion protections needs maintenance. | |
01/12/2010 | GRADING - INTERMEDIATE | Approved | SPOKE WITH DAVID FROM EAGLE ROCK REGARDING THIS PROJECT. CONTRACTOR IS ASKING FOR RELEASE LETTER FOR HIS PORTION OF THE PROJECT. INFORMED DAVID THAT THE GRADING PERMIT IS NOT READY FOR A FINAL INSPECTION DUE TO THE INCOMPLETENESS OF THE PROJECT. | |
07/22/2009 | GRADING - INTERMEDIATE | Approved | WAS CONTACTED BY DAVID YOUNG OF EAGLE ROCK CONSTURCTION (891-3057) HE WANTED TO BE ADVISED ON HOW TO ADDRESS CURB ENDS. I ADVISED DAVID TO CONTACT THAD HARVISON WITH COT PERMITS AND CODES TO SET UP A MEETING SO THAT WE CAN ALL DISCUSS HOW TO HANDLE THE TIE IN TO THE RIGHT OF WAY. MR YOUNG WILL GET IN TOUCH WITH ME WHEN A MEETING HAS BEEN SET. | |
06/02/2009 | GRADING - INTERMEDIATE | Partial Approval | Malena and I spot checked building pad elev. and they appear to be correct per the approved grading plan. | |
01/20/2009 | GRADING - INTERMEDIATE | Partial Approval | Contractor submitted revised drawing for wall to per EE. | |
01/07/2009 | GRADING - INTERMEDIATE | Partial Approval | Janc's is no longer the contractor for earth work. Eagle Rock is the new contractor. Went over requirements for site with Jose site super. | |
01/17/2008 | GRADING - INTERMEDIATE | Continued | Contractor filling site, construction entrance in place. I spoke to loader operator and asked that they establish grade elevations for cut and fill. They have placed approx. 3ft of fill along east edge of project. | |
01/15/2008 | GRADING - INTERMEDIATE | Continued | Checked on site asked contractor to install a construction entrance, they will begin hauling in fill tomorrow. | |
01/11/2008 | GRADING - INTERMEDIATE | Continued | met with contractor on-site, Randy (603-7899), he began grading yesterday. Not erosion controls required on plans because site is under 1 ac. |