Permit: T07BU00999

Parcel: 133381700

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Date Description Inspector Results Comments
08/27/2007 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection :*
08/23/2007 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. FILL HOLE IN PANEL AND SECURE DEAD FRONT
2. FILL HOLE AND INSTALL BLANKS AT MAIN PANEL
3. LABEL SUBPANEL BREAKER AT MAIN PANEL
4. CANNOT USE ROMEX IN CONDUIT; USE THHN OR THHW
5. MAXIMUM 4" SPACING ON FENCE VERTICLES
6. MAXIMUM 4" SPACE BETWEEN FENCE & GROUND
7. RUN INSULATED BOND WIRE FROM LUG IN LITE TO BOND IN JUNCTION BOX AND USE POTTING COMPOUND.