Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T07BU00976
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/23/2007 | MECHANICAL - FINAL | Approved | OK TO INSTALL FIRE SUPPRESSION SYSTEM | |
06/04/2007 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* TYPE 1 HOOD & GREASE DUCT ARE OK HOWEVER, THE PADDLE TYPE BLOWER WHEEL HAS BEEN REPLACED WITH A SQUIRREL CAGE (NOT APPROVED FOR TYPE 1) THE CLEANOUT IS OPEN & NOT TO CODE -- NEEDS 16 GA. STEEL ACCESS DOOR WITH WING NUTS. THE BELT & PULLEYS MUST HAVE A PROTECTIVE COVER. |