Inspection History Details
Inspection Status: Partial Approval
Inspection History: POOL/SPA FINAL/BARRIER
Permit Number - T07BU00899
Inspection Description - POOL/SPA FINAL/BARRIER
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/12/2007 | POOL/SPA FINAL/BARRIER | Partial Approval | IVRS - Inspection :* | |
07/02/2007 | POOL/SPA FINAL/BARRIER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL VACUUM BREAKER ON HOSE BIB 2) SECURE FENCE TO HOUSE 3) UNCOVER SPLIT BOLT THAT NEEDED TIGHTENING 4) INSTALL BONDING BUSHING ON CONDUIT AT PANEL 5) WALL ON SOUTH SIDE ONLY 4' HIGH 6) STABLIZE FENCE ON NORTH SIDE 7) WINDOW INTO POOL AREA MUST HAVE NON REVERSIBLE SCREW TO PREVENT OPENING OVER 4". CANNOT BE REQUIRED EMERGENCY EXIT 8) EXPOSE FITTINGS ON GAS PIPE TO PERMIT INSPECTION OF PRIMER UNDER TAPE 9) SVRS S/N #022984 |