Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/07/2007 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* COLUMNS SET IN PLACE: USED 4 @ #5 REBAR ON @ COLUMN IN PLACE OF 2 @ #7 REBARS -- OK TO POUR CAISSONS |
|
| 05/21/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 2 @ CAISSONS EXCAVATIONS 7'6" X 2'6" OK TO SET COLUMNS PLEASE LEAVE PERMIT & ACTIVITY CARD WITH PLANS AT JOB SITE -- THANK YOU |
|
| 05/15/2007 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* WORK HAS NOT BEGUN @ JOB SITE PLEASE RECALL WHEN CAISSONS HAVE BEEN EXCAVATED AND COLUMNS ARE READY FOR PLACEMENT. THANK YOU |