Permit: T07BU00593

Parcel: 118036090


Addresses:

2041 S HERMOSA DR


Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Permit Number - T07BU00593

Inspection Description - STEM WALL/RETAINING WALL

Inspection Status - Approved

Date Description Inspector Results Comments
06/04/2007 STEM WALL/RETAINING WALL Approved IVRS - Inspection :*
SPECIAL CONDITIONS #2 SPECIAL INSPECTION FOR STRUCTURAL MASONRY PER U.A.C SEC 306
REPORTS PROVIDED ON SITE
06/01/2007 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
NOTE: REMOVE VERTICAL REBAR ON TOP OF WALL AND PROVIDE SOLID CAP TO PREVENT CORROSION TRANSFER WHEN THE MASONRY REINFORCING IS EXPOSED TO WEATHER.

PROVIDE WALL DRAIN SYSTEM (G.SERIES DRAINAGE COMPOSITES) IN ACCORDANCE WITH REQ. PRIOR TO COVERING OR CONCEALING, FILL OR OTHER.
05/25/2007 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
EAST WALL @ 5'6" BOND BEAM WITH #5 HORIZONTAL REINFORCING RE-BAR
OK TO GROUT
05/18/2007 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
OK TO GROUT FIRST 4 COURSES OF CMU RTW

NOTE: BOND BEAM W/#5 BAR HORIZ. CONT. PROVIDED
SPECIAL INSPECTOR MUST VERIFY SETUP OF BAR AT LEAST COMPLETELY EMBEDDED IN GROUT 3/4" AT 1 1/2 OF COVER
VERTICAL REINFORCING #5 @ 8" O.C PROVIDED RFI BY ENGINEER OK
DRAIN SYSTEM OK BY ENGINEER, LETTER PROVIDED

MUST REQ. SPECIAL INSPECTION PRIOR TO GROUT AND HAVE REPORT IN COMPLIANCE (SPECIAL INSP)
AFTER GROUT BUILD THE NEXT COURSES WITH THE REINFORCING ADDRESSES ON APPROVED PLANS AND REQ. C.T.O INSPECTION PRIOR TO GROUT.
05/10/2007 STEM WALL/RETAINING WALL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE REBAR ON TOP OF 12" CMU, APPROVED PLANS CALL FOR BOND BEAM WITH #5 BAR HORIZONTAL AT 2'8"
OF 12" W CMU
2. VERTICAL REBAR #5 @ 8" O.C (C) PROVIDE REFERENCE FOR INFORMATION STAMPED BY ENGINEER REGARDING DOWELS INSTEAD REBAR FROM FOUNDATION
3. INFORMATION FOR GEOCOMPOSITE WALL DRAIN SYSTEM NEED TO BE APPROVED BY ENGINEER, PROVIDE LETTER FOR APPROVATION.
05/03/2007 STEM WALL/RETAINING WALL Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOTE:
1. PROVIDE LETTER STAMPED BY ENGINEER AND DSD CITY OF TUCSON REGARDING REBAR COVER WITHOUT INSPECTION AND USE A MORTAR INSTEAD OF GROUT.
2. VERIFY DETAIL OF 2ND VERTICAL REBAR REPLACEMENT
3. PROVIDE MANUFACTURER'S INSTALLATION PROCEDURES FOR WALL DRAIN SYSTEM.
4. PROVIDE SPECIAL INSPECTION REPORT AS WELL AS CONFIRMATION OF REBAR COVERED W/O INSPECTION
5. OR REMOVE WORK COVER WITHOUT INSPECTION VERIFY APPROVED PLANS FOR COMPLIANCE.
04/30/2007 STEM WALL/RETAINING WALL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. MUST CALL FOR INSPECTION PRIOR TO COVERING OR CONCEALING WORK SECT. 109.1 IBC
2. PROVIDE SPECIAL INSPECTION FOR STRUCTURAL MASONRY REQUIRED PER U.A.C SECTION 306 (SPECIAL CONDITIONS ON PERMIT)
3. NOT APPROVED FOR GROUT, MUST PROVIDE CORRECT REINFORCING IN PLACE AND SPECIAL INSP. REPORT
4. POSSIBLE MORTAR ON CELLS, PRIOR TO GROUTING, THE GROUT SPACE SHALL BE CLEAN SO THAT ALL SPACES TO BE FILLED WITH GROUT DO NOT CONTAIN MORTAR OR OTHER FOREIGN MATERIAL. GROUT SHALL BE PLACED SO THAT ALL SPACES DESIGNATED TO BE GROUTED SHALL BE FILLED WITH GROUT.