Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: GRADING - INTERMEDIATE
Permit Number - T07BU00352
Inspection Description - GRADING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/07/2015 | GRADING - INTERMEDIATE | Approved | ||
01/18/2012 | GRADING - INTERMEDIATE | Continued | CONTACTED ZACH HINMAN AND ADVISED HIM OF THE SIGN SIZE FOR THE "NO PARKING". IN ALL LOCATIONS THEY ARE TO BE AN R8-3A 12" x 12", SOME LOCATIONS REQUIRE A SUPPLEMENTAL PLAT THAT IS A 6" x 12" LABELED BEGIN OR END DEPENDING ON THE LAYOUT LOCATION. | |
11/02/2011 | GRADING - INTERMEDIATE | Continued | WAS CONTACTED BY THE REGISTERED LAND SURVEYOR AND ADVISED HOW THE SURVEY MONUMENTS WERE LAID OUT, SITE CHECK SHOWS THAT ALL CURRENT MONUMENTS ARE WITHIN THE CITY TOLERANCES. | |
01/04/2011 | GRADING - INTERMEDIATE | Continued | NO CONCERNS AT THIS TIME. DEVELOPER IS STILL WORKING ON CONSTRUCTING HOUSES, BUT IS PROGRESSING SLOWLY DUE TO THE CURRENT MARKET. I STARTED CHECKING THE SURVEY MONUMENTS FOR THIS SITE AFTER FINDING ERRORS IN SOME OF THE OTHER SITES FOR THIS DEVELOPER. THE MONUMENTS THAT I HAVE CHECKED APPEAR TO BE WITHIN TOLERANCE FOR MEASUREMENT, BUT WILL BE RECHECKED FOR ACCURACY PRIOR TO FINALING THE ASSURANCES FOR THIS SUBDIVISION. | |
02/09/2010 | GRADING - INTERMEDIATE | Continued | NO STORM WATER CONCERNS AT THIS TIME. CONTRACTOR WORKING ON CONSTRUCTION OF HOUSES AT VARIOUS LOTS, INFRUSTRUCTURE IS COMPLETE. |
|
01/29/2010 | GRADING - INTERMEDIATE | Continued | ALL GRADING ISSUES AND CONCERNS WILL BE ADDRESSED UNDER PERMIT #T07BU00352. MOST SITE WORK COMPLETED, SOME MINOR GRADING W/ INDIVIDUAL LOTS REMAIN. STORM WATER CONCERNS ARE MINIMAL, HOWEVER SITE IS NOT BUILT OUT. | |
09/16/2009 | GRADING - INTERMEDIATE | Continued | SOME DISCREPANCY WITH EXISTING VERTICAL CURB VERSES WEDGE CURB IN RELATION TO THE FFE OF THE HOUSES COMPARED TO THE ROAD ELEVATION. IT APPEARS THAT THERE IS NOT ENOUGH ROOM BETWEEN THE ROAD AND THE HOUSE TO FIT A WEDGE CURB, SIDEWALK, AND DRIVEWAY. | |
09/10/2009 | GRADING - INTERMEDIATE | Continued | SITE WORK IS SUBSTANTIALLY COMPLETED, SOME STABILIZATION WORK AND REPAIR LEFT TO BE DONE. NO SIGNIFICANT STORM WATER CONCERNS ON SITE. RESIDENTIAL LOTS NOT STABILIZED, CONTRACTOR BLDG ON 4 LOTS. NEED ENGINEER CERT PRIOR TO FINAL APPROVAL |
|
09/03/2009 | GRADING - INTERMEDIATE | Continued | CONTRACTOR IS WORKING ON BLDG TWO HOMES ON SITE, SITE WORK INFRUSTRUCTURE IS COMPLETED, NEED TO STABILIZE REMAINING LOTS. | |
06/17/2009 | GRADING - INTERMEDIATE | Continued | INFRASTRUCTURE HAS BEEN CONSTRUCTED TO INCLUDE ROADS, SIDEWALKS, BLDG PADS, AND STORM DRAINAGE WAYS, HOWEVER THE SITE HAS NOT BEEN STABILIZED. THERE WAS NO ACTIVITY ON THE SITE AND NO CONTACT INFORMATION AVAILABLE. |
|
04/27/2009 | GRADING - INTERMEDIATE | Continued | SITE WORK IS COMPLETE EXCEPT FOR SOIL STOCKPILE. HALF OF THE STOCKPILE WAS REMOVED. |
|
02/02/2009 | GRADING - INTERMEDIATE | Partial Approval | SITE WORK IS ALMOST COMPLETE. UTILITY PEDESTAL WORK IS IN PROGRESS. |
|
09/18/2008 | GRADING - INTERMEDIATE | Continued | NORTH PERIMETER SLOPE PARTIALLY GRADED. R/D BASINS ARE GRADED CURBS ARE IN PLACE STREET SUBGRADE BLUE TOP IS IN PROGRESS AND A/B APPLICATION WILL BEGIN. |
|
09/11/2008 | GRADING - INTERMEDIATE | Continued | ROCK RIP RAP IS BEING CONSTRUCTED IN R/D BASIN. NORTH SLOPE NEEDS TO BE TRIMMED TO 3:1 |
|
06/12/2008 | GRADING - INTERMEDIATE | Correction Required | GRADE MUST MATCH EXISTING GRADE FOR A MINIMUM OF 2' INSIDE THE PROPERTY LINE BEFORE THE FILL SLOPE. |