Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ENGINEERING PRE-CONSTRUCTION
Permit Number - T07BU00215
Inspection Description - ENGINEERING PRE-CONSTRUCTION
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2008 | ENGINEERING PRE-CONSTRUCTION | Approved | REVIEWED SWPPP CONTRACTOR HAS ESTABLISHED A DEFINED GRADING LIMIT. A STABILIZED CONSTRUCTION ENTRANCE HAS BEEN INSTALLED. MOST PERIMETER SEDIMENT CONTROLS (SILT SOCK) HAVE BEEN INSTALLED. CONTRACTOR MUST INSTALL A CONCRETE/MATERIALS WASH-OUT ON SITE AND CONTINUE TO SWEEP UP TRACKING OFF OF PUBLIC ROADWAY. CONTRACTOR WANTS TO CHANGE APPROVED GRADING PLAN BY NOT INSTALLING CURBING ON PRIVATE ROADWAY, AND INSTALLING A THICKENED EDGE WITH A ROCK RIP RAP BORDER. ENSURE MAINT SELF INSPECTIONS ARE PERFORMED AND DOCUMENTED. CONTRACTOR: LEE 850-7990 SWPPP GUY: JAY KNOLL 425-0920 OWNER: LUIS YBARRA 603-2287 |
|
| 07/31/2008 | ENGINEERING PRE-CONSTRUCTION | Not ready for Inspection | NO ACTIVITY ON SITE |