Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T06VL01156

Parcel: 132110220

Inspection Status: Approved

Inspection History: INITIAL CODE VIOLATION

Date Description Inspector Results Comments
11/01/2006 INITIAL CODE VIOLATION Approved VISITED SITE, FOUND FRONT PORCH HAD BEEN REMOVED FROM THE ROOF AND MATERIALS TAKEN FROM THE SITE. THE SIDE PORCH AND THE FRONT PORCH HAD BOTH BEEN REBUILT. PERMITS WERE NOT REQUIRED. FRONT PORCH 7'X20' AND SIDE PORCH 6'X8'. EXISTING LEDGERS WERE USED ON BOTH PORCHES, RAFTERS WERE NOW CLIPPED TO THE LEDGER AS RAFTERS SET ON TOP OF THE LEDGER. RAFTERS ALSO CLIPPED TO BEAMS, SEEMS HAD PAST CLIPS, TO THE POST AND BEAM AND PROPER POST BASES WERE USED. ROLLED ROOFING WHERE NEW ROOF MEETS EXISTING WAS ROLLED UP UNDER DRIP EDGE. BOTH PORCHES WERE BUILT TO CODE. PICTURES WERE TAKEN OF PORCHES AND CONNECTING HARDWARE, CONCRETE SLABS WERE ALSO EXISTING.