Permit: T06PL02432

Parcel: 112040950


Addresses:

2901 N FORGEUS AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL02432

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/27/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
REAR HOUSE HAS BEEN DISCONNECTED FROM FRONT HOUSE GAS PIPING. LEFT GAS CARD.
01/31/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PRESSURE TEST ON MAIN HOUSE ONLY OK
2. PIPING AT STOVE OK
3. PROVIDE PETITION OF APPEAL FOR T&P TERMINATION INSIDE HOME.
01/30/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
TIED WITH T07ME00033

NO ACCESS 250 PM
PROVIDE LADDER TO ROOF
CANNOT ALLOW T&P TO DRAIN TO LAUNDRY STAND PIPE
THIS IS NOT AN EXISTING SITUATION
01/24/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE ALL NOTES, PROVIDE TEST ON SYSTEM & COMPLY
SHALL HAVE RIDGID PIPING THRU CABINET SPACE WITH FLEX ON EXTERIOR OF CABINETS. CANNOT CONNECT 2 FLEXES TOGETHER. RETEST SYSTEM IN ENTIRETY.
01/22/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE PROOF OF INSPECTION OF BOTH NEW ROOFTOP UNITS.
2. PROVIDE 3-GALV SCREWS AT EACH JOINT OF WATER HEATER VENT PIPING.
3. SECURE PIPING AT DROP AT METER AND REMOVE FUTURE TEE CONNECTION OR PROVIDE CITY APPROVED PLAN OF ENTIRE GAS SYSTEM.
01/04/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ADD "REPLACE WATER HEATERS" TO PERMIT
BOTH UNITS
COMPLETE INSTALLATION OF WHS
VENTING, T&P TO EXTERIOR
INSTALL SEDIMENT TRAPS AT WHS AND FURNACES
EXPOSE BELOW GROUND 90 DEG. TO INSPECT PIPE WRAPS