Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06PL02412
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/29/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
12/28/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 25 PSI TEST, LEAVE TEST ON, IF STILL HOLDING AT NEXT INSPECTION IT WILL BE OK 2) SECURE PIPING AT WH 3) SUPPORT PIPING ON ROOF 4) EXTEND B-VENT AT WH TO 1' ABOVE SIDE ROOF 5) PROVIDE 1" OF CLEARANCE FROM WOOD AT B-VENT 6) PROVIDE COMBUSTION AIR OPENING FOR WH |