Permit: T06PL02366

Parcel: 106040290


Addresses:

415 E YAVAPAI RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/06/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
04/04/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. I WILL NOT RELEASE GAS TO AN UNAPPROVED APPLIANCE
YOU HAVE BEEN ASKED ON 1/24/07 AND AGAIN ON 3/27/07 TO SECURE A PERMIT FOR THE WATER HEATER AND HAVE IT APPROVED BEFORE THE GAS CAN BE RELEASED.
2. CONTINUED NOT READYS WILL RESULT IN A REINSPECTION FEE.
03/27/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. WATER HEATER INCOMPLETE - STILL NO PERMIT
2. EXPOSED EXTERIOR WATER PIPING TO BE INSULATED
3. AIR INTAKES WITHIN 10' OF VENTS AND FLUES
4. REQUIRE DRIP LEGS (SEDIMENT TRAPS) AT WATER HEATER AND FURNACE.
5. REQUIRE BOND BETWEEN GAS PIPE AND WATER PIPE
6. PVC UNION NOT APPROVED
DIELECTRIC SEPARATOR BETWEEN GALV. & COPPER
01/24/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. GAS LINE MAY NOT RUN UNDER THE BLDG.
PVC WATER NOT APPROVED FOR UNDER THE BLDG.
2. ALL FITTINGS AND MARRED SCOTCHCOAT TO BE PRIMED AND TAPED.
3. WATER HEATER MAY NOT BE LOCATED OUTSIDE WITHOUT PROTECTION NEW WATER HEATER REQUIRES PERMIT.
4. PIPE TO BE WRAPPED WHERE PASSING THROUGH EXTERIOR WALL - EXTERIOR WALL PENETRATION TO BE SEALED.
5. USE CORRECT GAUGE - NO TEST ON SYSTEM.
6. PIPING PASSING THRU ROOF TO HAVE APPROVED ROOF JACK.
7. GAS VALVE FOR FURNACE TO BE WITHIN THREE FEET AND ACCESSIBLE.
8. TRACER ONLY REQUIRED ON NON-METALLIC UTILITIES.
9. ROOFTOP PIPING TO BE SUPPORTED IN AN APPROVED MANNER.