Permit: T06PL02359

Parcel: 11106054A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/22/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
12/21/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PRESSURE TEST IS HOLDING, OK TO COVER PIPING
2. WATER HEATER HAS BEEN RELOCATED WITHOUT PERMITS
3. WATER HEATER SHALL REST ON A CONCRETE SLAB OR APPROVED BASE.
4. WH SHALL BE PROTECTED FROM WEATHER BY AN ENCLOSURE.
5. WH VENT SHALL BE DOUBLE WALL WHERE EXPOSED AND INSTALLED W/PROPER CLEARANCE FROM COMBUSTIBLES.
6. SECURE CONNECTOR W/SCREWS
7. T&P SHALL BE OF APPROVED MATERIAL
8. INSTALL SEDIMENT TRAPS AT WH & FURN
9. SUPPORT PIPING ON ROOF