Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PLEASE DON'T KEEP THE INSPECTOR WAITING 2. PRIVATE MANHOLE CONTRACTOR YOU MAY WANT TO PRE-TEST MANHOLE BEFORE HAVING THE INSPECTOR ARRIVE. |
|
| 01/08/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 48" X 9' MANHOLE 10 POUNDS VACUUM HELD FOR 20 SECONDS OK THIS COMPLETES PRIVATE SEWER |
|
| 01/04/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1. 8" PVC PRIVATE SEWER FROM PUBLIC MANHOLE TO PRIVATE MANHOLE. 2. FIVE POUND AIR TEST HOLDING STEADY FOR 150 SECONDS OK 3. RECALL FOR VACUUM TESTING OF PRIVATE MANHOLE |
|
| 01/03/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |