Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06PL02312
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/19/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
12/18/2006 | PLUMBING - FINAL | Denied | 1. SHALL PROVIDE BONDING OF BUILDING GAS PIPING. 2. PROVIDE APPROVED TRANSITION FROM SINGLE WALL FURNACE VENT TO DOUBLE WALL VENT PIPING. 3. REMOVE TAPE AT DRAFT SPACE ON SINGLE TO DOUBLE WALL VENT OF WATER HEATER. 4. PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING OF WATER HEATER & FURNACE VENTS. 5. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO WATER HEATER & FURNACE. 6. SECURE & SUPPORT PIPING IN WATER HEATER/FURNACE CLOSET. 7. THREAD PROTECTORS ARE NOT APPROVED COUPLINGS (ON ROOF) AND SUPPORT PIPING TO DRYER AND AT CORRECT INTERVALS WITH WEATHER RESISTANT MATERIAL. 8. SEAL ROOF JACK AT #7 LOCATION TO PROVIDE WEATHER SEAL. RETEST & MAKE CORRECTIONS. |