Inspection History: PLUMBING - FINAL

Permit Number - T06PL02312

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/19/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
12/18/2006 PLUMBING - FINAL Denied 1. SHALL PROVIDE BONDING OF BUILDING GAS PIPING.
2. PROVIDE APPROVED TRANSITION FROM SINGLE WALL FURNACE VENT TO DOUBLE WALL VENT PIPING.
3. REMOVE TAPE AT DRAFT SPACE ON SINGLE TO DOUBLE WALL VENT OF WATER HEATER.
4. PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING OF WATER HEATER & FURNACE VENTS.
5. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO WATER HEATER & FURNACE.
6. SECURE & SUPPORT PIPING IN WATER HEATER/FURNACE CLOSET.
7. THREAD PROTECTORS ARE NOT APPROVED COUPLINGS (ON ROOF) AND SUPPORT PIPING TO DRYER AND AT CORRECT INTERVALS WITH WEATHER RESISTANT MATERIAL.
8. SEAL ROOF JACK AT #7 LOCATION TO PROVIDE WEATHER SEAL.

RETEST & MAKE CORRECTIONS.