Permit: T06PL02309

Parcel: 112052710


Addresses:

2231 E GLENN ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL02309

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/19/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
12/18/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
T&P DEVICE SHALL BE FUNCTIONAL
12/15/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SHALL PROVIDE SEDIMENT TRAPS AT FURNACE & WATER HEATER.
2. SHALL PROVIDE BONDING OF BUILDING GAS PIPING.
3. WATER HEATER TEMPERATURE & PRESSURE RELIEF SHALL GRAVITY DRAIN TO DAYLIGHT TERMINATING WITH 96 DEG. DOWN.
4. SECURE GAS PIPING IN WATER HEATER & FURNACE CLOSET.
5. PROVIDE 3-GALV SCREWS AT EACH JOINT OF WATER HEATER VENT PIPING.
6. SHALL PROVIDE ROOF FLASHINGS ON PIPE PENETRATIONS THRU ROOF.
7. PROVIDE WATER RESISTANT SUPPORTS FOR ROOFTOP PIPING.
8. VENT FROM WATER HEATER TO BE DOUBLE WALL THRU ROOF MINIMUM 2' ABOVE AIR INTAKE WHEN WITHIN 10' TERMINATING WITH APPROVED VENT CAP.