Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 12/18/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PIMA/SWAN ENTER OFF OF ARCADIA NOT 3800 S 1. FLASHINGS REQUIRED AT ROOF PENETRATION 2. LISTED COUPLINGS REQUIRED 3. NEW WH REQUIRES PERMIT AND MUST BE COMPLETE FOR GAS SERVICE. 4. NEW FLEX REQUIRED, T&P REQUIRED TO GRAVITY DRAIN TO EXTERIOR OR PROVIDE A PETITION OF APPEAL AND INSTALL DRAIN PAN AND 125 PSI PRV AT EXTERIOR HOSE BIB. 5. WH AND FURN REQUIRE SEDIMENT TRAPS 6. PROVIDE ELECTRICAL BONDING 7. WRAP TOOL MARKS AND FITTINGS ON SCOTCH-KOTE PIPING BELOW GRADE. |