Permit: T06PL02289

Parcel: 115221200


Addresses:

1411 W HUALPAI RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/13/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
12/12/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. TEMPERATURE & PRESSURE RELIEF DEVICE ON WATER HEATER TO FUNCTION PROPERLY. IT IS LEAKING.
WATER HEATER T&P DRAIN SHALL BE GRAVITY DRAIN TO DAYLIGHT WITH ALL CONNECTIONS SOLDERED PROPERLY &
90 DEG. TERMINATION AT EXTERIOR.
2. PRIME & TAPE RISER PIPE AT BUILDING TO 6" ABOVE FINISH GRADE.
3. SEAL PIPE PENETRATION INTO BUILDING AT ATTIC.
4. SECURE BLACK IRON PIPING IN ATTIC SPACE.