Permit: T06PL02281

Parcel: 112052510


Addresses:

2828 N WILSON AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/15/2006 PLUMBING - FINAL Approved 1. CORRECTIONS MADE OK
2. OK FOR GAS
UCC LEFT AT METER
SW GAS 889-1888
12/13/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PETITION OF APPEAL #2006-236 ON SITE
1. TEST SHALL HOLD FOR 10 MINUTES WITH NO LOSS OF PRESSURE.
2. PROVIDE NIPPLE WITH NO THREADS IN DISCHARGE END AT 125 # PRESSURE RELIEF DEVICE.
3. SEAL PIPE PENETRATION THRU COMBUSTION AIR INTAKE.
12/11/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. T&P SHALL GRAVITY DRAIN TO EXTERIOR OR PROVIDE A PETITION OF APPEAL FROM PERMIT COUNTER.
2. PET. OF A REQUIRES A DRAIN PAN AND EXTERIOR 125 PSI RELIEF VALVE.
3. SECURE WH VENT W/SCREWS
4. PROVIDE ELECTRICAL BONDING
5. PROVIDE SEDIMENT TRAPS AT WH & FURN
6. SUPPORT PIPING ACROSS ROOF AT EVERY 8' AND AT APPLIANCES, USE WEATHER RESISTANT PIPE SUPPORTS AND CLAMPS.
7. DON'T STRAIN PIPING - USE FITTINGS TO OFFSET
8. USE FULL SIZE TEE - 3/4, 1/2 - 1/2