Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) CORRECTIONS MADE OK 2) OK TO COVER ALL AREAS 3) OWNER TO NOTIFY CONTRACTOR IF HE HEARS ANY BANGING PRIOR TO DRYWALL |
|
| 12/13/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SHALL PROVIDE FULL SIZE 1" TO TEE BRANCH THAT IS 3/4" FOR DISTRIBUTION AT SERVICE AREA. 2. SHALL PROVIDE SAFETY PLATES AT AREAS WHERE PIPING IS WITHIN 1 1/4 OF FACE OF STUD. 3. SHALL SUPPORT ALL OVERHEAD PIPING AT CORRECT INTERVALS PER 2003 UPC FOR 1/2" & 3/4" COPPER PIPING. AND IN WALL PIPING. WATER HEATER WIRING IS SHORTED AT MAKE UP BOX IN HEATER, LEAVE WATER HEATER BREAKER OFF UNTIL THIS PROBLEM IS SOLVED, IF A NEW WATER HEATER IS REQUIRED PLEASE SUPPLY CITY PERMIT FOR THIS. |
|
| 12/08/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PROVIDE GATE CODE REQUIRED FOR ENTRY SECURE HOSE BIBBS PROVIDE ACCESS TO NEW PIPING NO ANSWER 2:44 - 2:49 PM |