Permit: T06PL02220

Parcel: 103213950

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/29/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS MADE OK
2) OK TO COVER ALL AREAS
3) OWNER TO NOTIFY CONTRACTOR IF HE HEARS ANY BANGING PRIOR TO DRYWALL
12/13/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SHALL PROVIDE FULL SIZE 1" TO TEE BRANCH
THAT IS 3/4" FOR DISTRIBUTION AT SERVICE AREA.
2. SHALL PROVIDE SAFETY PLATES AT AREAS WHERE PIPING IS WITHIN 1 1/4 OF FACE OF STUD.
3. SHALL SUPPORT ALL OVERHEAD PIPING AT CORRECT INTERVALS PER 2003 UPC FOR 1/2" & 3/4" COPPER PIPING. AND IN WALL PIPING.

WATER HEATER WIRING IS SHORTED AT MAKE UP BOX IN HEATER, LEAVE WATER HEATER BREAKER OFF UNTIL THIS PROBLEM IS SOLVED, IF A NEW WATER HEATER IS REQUIRED PLEASE SUPPLY CITY PERMIT FOR THIS.
12/08/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PROVIDE GATE CODE REQUIRED FOR ENTRY
SECURE HOSE BIBBS
PROVIDE ACCESS TO NEW PIPING
NO ANSWER 2:44 - 2:49 PM