Permit: T06PL02211

Parcel: 133352550


Addresses:

9011 E 3RD ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/28/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
12/19/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
ALL PIPING IS OK
NEW WATER HEATER T&P IS REQUIRED TO GRAVITY DRAIN TO BUILDING EXTERIOR OR APPLAY FOR A PETITION OF APPEAL TO TERMINATE T&P INSIDE.
12/08/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. COMPLETE PIPING TO APPLIANCES AND PRESSURE TEST ENTIRE SYSTEM WITH GAUGE.
2. PROVIDE T&P GRAVITY DRAIN TO EXTERIOR
3. PROVIDE ELECTRICAL BONDING
4. SEDIMENT TRAPS REQUIRED AT WH AND FURN
5. 3/4 CAN SUPPLY TO 1" MAIN
6. CAP UNUSED OUTLETS AT FP, BARBECUE AND STOVE
7. PRIME AND WRAP TOOL MARKS BELOW GRADE.