| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 11 PSI 8:58 |
|
| 12/08/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE 1" CLEARANCE AT B VENT 2. PROVIDE ELECTRICAL BONDING 3. PROVIDE SEDIMENT TRAP AT FURN 4. PROVIDE FLASHING AT ROOF PENETRATION 5. PROVIDE TYPE L COPPER AT EXTERIOR 6. PROVIDE AIR PRESSURE TEST W/15 PSI GAUGE WITH 1/10 PSI INCREMENTS. |