Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06PL02201

Parcel: 126060680


Addresses:

4218 E HAWTHORNE ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/11/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
11 PSI 8:58
12/08/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE 1" CLEARANCE AT B VENT
2. PROVIDE ELECTRICAL BONDING
3. PROVIDE SEDIMENT TRAP AT FURN
4. PROVIDE FLASHING AT ROOF PENETRATION
5. PROVIDE TYPE L COPPER AT EXTERIOR
6. PROVIDE AIR PRESSURE TEST W/15 PSI GAUGE WITH 1/10 PSI INCREMENTS.