Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06PL02188
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/15/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS CARD ON PIPE AT METER TAPE THE TWO COUPLINGS BEFORE POURING |
|
12/13/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. WATER HEATER TEMPERATURE & PRESSSURE RELIEF PIPING SHALL GRAVITY DRAIN TO DAYLIGHT WITH FULL SIZE APPROVED MATERIAL. 2. PROVIDE SCREWS AT JOINTS OF FLUE PIPING. FOR WATER HEATER & FURNACE. 3. PROVIDE BONDING OF BUILDING GAS PIPING. 4. SHALL EXTEND FURNACE VENT WITH DOUBLE WALL VENT PIPING 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE WITH VENT CAP. 5. PROVIDE CSA OR AGA APPROVED GAS VALVES AT APPLIANCES. 6. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO FURNACE & WATER HEATER. |
|
11/29/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* CALLED & MADE CONTACT AT 304-8174 WAS TOLD YOU WOULD ARRIVE IMMEDIATELY. WAITED FOR APP. 10 MINUTES. 1. SHALL PROVIDE TEST ON ENTIRE GAS SYSTEM AT TIME OF REINSPECTION. 2. SHALL HAVE ADULT PRESENT TO PROVIDE ACCESS TO GAS SYSTEM. 3. IT APPEARS YOU HAVE AN UNAPPROVED REPAIR COUPLING AT HOUSE SERVICE ENTRY THAT WILL REQUIRE REPAIR. THIS IS NOT A COMPLETE LIST. |