Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/07/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 12/06/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* | |
| 12/04/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE ROOF JACK ON PIPING PENETRATION THRU ROOF 2. PROVIDE CORRECT SUPPORT & SECURE ROOFTOP GAS PIPING. 3. SHALL PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVES AT ALL APPLIANCES WITH GAS FLEX RATED FOR BTU'S OF APPLIANCE. 4. FUTURE TEES REQUIRE APPROVED GAS ISOMETRIC PLANS BY CITY OR SHALL BE REMOVED FROM SYSTEM. 5. SUPPORT GAS PIPING AT WATER HEATER LOCATION & DOOR LOCATION. 6. PROVIDE BONDING OF BUILDING GAS PIPING. 7. WATER HEATER TO HAVE COMPLETE CONNECTION FOR VENT AND T&P DEVICE. SEAL PIPE ENTRY INTO BUILDING. |