Permit: T06PL02122

Parcel: 131020770


Addresses:

5358 E 26TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/24/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
SW GAS 889-1888
11/20/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- 13 PSI TEST IS OK
- APPLY THE TAPE PRIMER PRIOR TO TAPING FITTINGS.
- PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS.
- PROVIDE APPROVED SHUT OFF VALVE AT WATER HEATER.
- GAS FLEX CANNOT PASS THROUGH THE FURNACE CABINET.
- BOND THE GAS PIPE TO THE ELEC. SYSTEM
- PROVIDE HIGH & LOW COMBUSTION AIR OPENINGS INTO FURNACE CLOSET .