Permit: T06PL02100

Parcel: 131060250


Addresses:

2445 S CRAYCROFT RD

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/28/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
11/28/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
GAS CARD LEFT ON SITE
11/17/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
20 PSI TEST IS OK
PROVIDE PERMIT, ENGINEERED DRAWING & SCHEDULE INSPECTIONS FOR NEW TYPE 1 HOOD INSTALLED.
NO GAS UNTIL HOOD HAS BEEN INSPECTED.
BE SURE TO INCLUDE NEW WALK IN COOLER & RELATED EQUIPMENT. ALSO, INCLUDE ELECTRICAL.
11/16/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
EXISTING GAS SYSTEM IS LOCKED OUT
EXISTING GAS SYSTEM IS 2" PIPE SIZE
PLAN DOES NOT REFLECT EXISTING PIPING
PROVIDE AN ACCURATE PLAN OF GAS PIPING SYSTEM.
PROVIDE PROOF OF MECHANICAL INSPECTION FOR NEW FAV
SEDIMENT TRAPS REQUIRED AT FAN
SUPPORT PIPING ACROSS ROOF
INSTALL CORRECT SIZE NEW FLEX AT WH
TERMINATE T&P OVER FS W/1" AIR GAP
SECURE FLUE W/SCREWS
RAISE B-VENT TERMINATION WITHIN 10' OF COOLER
COMPLY W/NOTES FROM C OF O INSP.