Permit: T06PL02040

Parcel: 12306070A


Addresses:

2225 E ADAMS ST

Inspection Status: Partial Approval

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/30/2006 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
1. 15 PSI TEST ON PIPING PER APPROVED PLAN IS OK
GAS SYSTEM IS CURRENTLY ON, MAKE CORRECTIONS, HAVE REINSPECTION.
2. SHALL SEAL PIPE ENTRY INTO BUILDING.
3. AT CHANGE OVER FOR ADDITION OF THIS GAS SYSTEM SHALL PERM CAP & OR SUPPORT OLD PIPING ON METER YARD AREA.
4. PROVIDE BONDING OF BUILDING GAS PIPING.
5. COMPLETE VENTING REQUIREMENTS FOR ALL GAS APPLIANCES.
6. SUPPORT ROOFTOP GAS PIPING AT NEW ROOFTOP UNIT SHUT OFF VALVE ON THIS SYSTEM.
11/28/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. PROVIDE DRAWING FOR GAS PIPING THAT HAVE BEEN APPROVED BY THE CITY.
2. HAVE PLUMBER ON SITE